top of page



.jpeg)





GENERAL SERVICE ADMINISTRATION
GENERAL SERVICES - FED-STD-809E
INSPECTION, MAINTENANCE, NEUTRALIZATION AND REPAIR OF GSA APPROVED CONTAINERS, LOCK EXTENSIONS AND VAULT DOORS
We are certified in opening, repairing, inspecting and recertifying GSA Containers, Field Safes, 1 Drawer Special Size, Shipboard Containers, 2 Drawer, 4 Drawer and 5 Drawer Security Containers, Map and Plans Containers, Weapons Containers, General Purpose Containers, IPS Containers, SCIF (Sensitive Compartmented Information Facility) Doors and Vault doors.


When drilled, a container must meet FED-STD-809E in neutralization and repair or else the containers label will be voided and cannot store and secure what its intended to.

Certified and trained in FFL-2740B and FFL-2937. These locks are locks approved for GSA Containers and Vault doors. We are certified and have knowledge of opening, operating, installing and troubleshooting the KABA MAS X-10, KABA MAS CDX-10, SARGENT AND GREENLEAF 2740B and SARGENT AND GREENLEAF 2937 mechanical and electromechanical locks.


We can factory reset locks on site with lost or unknown combinations. This only applies to locks that are not on a locked container or door! Once the factory reset is performed, the security manager will then change the combination to his or her choosing and document the new combination. This can save a $1000 or more and keep a great lock from being wasted!
We have experience with the following manufacturers: Hamilton, Will-Burt, Alpha Safe, American Made Safe and Security, Mosler, Diebold-Mosler, A&H Security Cabinets, Diebold, Overly door company, Brown Safe and more.



When choosing a tech to work on this hardware, it is important to make sure that they know what they are doing and can successfully accomplish the mission. Doing the wrong thing can result in serious consequences and can lead to a total container replacement!
This Education and training can only be found in a few places. We have undergone this to be able to properly service you and keep you compliant with federal standards and specifications. These openings are advanced level openings and need to be well thought out before action is taken.
Just an example. A Security Manager had a 2 drawer Class 6 Red label with a supposed unknown combination. We dialed in the factory combination first but, it did not open. We pulled all information and records of the container but, no combos would open the lock. This lock is extremely expensive and showed signs to be working properly. We did not drill the lock! Instead, we defeated the bolt work of the container and did a factory reset on the lock once it was opened. We replaced the control drawer head, installed the existing lock onto the new control drawer and had the security manager change the combination. Taking this route saved the customer around $1300! Hiring the wrong person can burn holes in your pocket.

.jpeg)
Copyright © 2025 EAST COBB LOCK AND KEY ALL RIGHTS RESERVED
bottom of page